Circuit breakers are mechanical switching devices that provide overload and fault protection for cables and other devices used in electrical distribution systems. The circuit breaker also serves as a means of manually disconnecting circuits.
Actron Circuit Breaker Brochure Part 1 and
Part 2
| Actron Molded-Case Circuit Breakers, 500 VAC, 3 Pole |
| Frame Size |
Frequency |
Ampere Rating |
Interrupting Capacity (Amps) |
| AQB-A102 |
60Hz |
15-100 |
15,000 |
| AQB-A102 |
400Hz |
15-100 |
10,000 |
| AQB-A102 Fused |
60Hz, 400Hz |
15-100 |
100,000 |
| NQB-A102 |
60Hz, 400Hz |
100 |
- |
| AQB-A252 |
60Hz |
100-250 |
20,000 |
| AQB-A252 |
400Hz |
100-250 |
10,000 |
| NQB-A252 |
60Hz, 400Hz |
250 |
- |
| AQB-LF252 |
60Hz |
125-250 |
100,000 |
| AQB-A402 |
60Hz |
250-400 |
30,000 |
| AQB-A402 |
400Hz |
250-400 |
10,000 |
| NQB-A402 |
60Hz, 400Hz |
400 |
- |
| AQB-LF402 |
60Hz |
250-400 |
100,000 |
| AQB-A802 |
60Hz |
400, 800 |
50,000 |
| AQB-A802 |
400Hz |
400, 800 |
10,000 |
| NQB-A802 |
60Hz, 400Hz |
800 |
- |
| AQB-A1604 |
60Hz |
600-1600 |
75,000 |
| NQB-A1604 |
60Hz |
1600 |
- |
|
None of the Above |
|
|
Molded-Case Circuit Breakers
L-3 SPD Electrical Systems Actron molded-case circuit breakers offer state monitoring capabilities previously unavailable in Navy circuit breakers. As the only manufacturer of a complete line of Navy molded-case circuit breakers, L-3 SPD Electrical Systems offers a full range of frame sizes and current ratings for 60 and 400 Hz applications, including molded-case circuit breakers with fuses for fault current limitation. The molded-case circuit breakers typically are used in lighting and distribution panels, power distribution switchboards, IC switchboards, fire control switchboards and motor control centers. Actron molded case circuit breakers comply with specification MIL-C-17361 (AQB) or MIL-C-17588 (ALB).
State Monitoring provides monitoring of the following features:
- Ground Fault
- Type & Phase of Last Trip
- Phase Current
- Current Data Logging
- Bidirectional Communication
- Remote Opening & Closing of Circuit Breaker
| Actron Air Circuit Breakers, 500 VAC |
| Frame Size |
Frequency |
Ampere Rating |
Interrupting Capacity |
| ACB-1606HRC |
60Hz |
1600 |
85,000 |
| ACB-2010HRC |
60Hz |
2000 |
85,000 |
| ACB-4010HR |
60Hz |
4000 |
85,000 |
| None of the Above |
|
|
Air Circuit Breakers
L-3 SPD Electrical Systems Actron air circuit breakers offer state monitoring capabilities previously unavailable in Navy circuit breakers. Actron air circuit breaker features allow increased automation and reduced manning through local and remote state monitoring, bidirectional communications, control functions, undervoltage dropout, undervoltage lockout, power-up trip, charging motor protection and more. Each Actron air circuit breaker has continuous current settings and standard features included, and requires only a change in switch settings to reconfigure the circuit breaker.
The Actron series represents a whole new generation of "smart", tough, reliable circuit breakers that have won the United States Navy's QPL approval rating, and comply with Military Specification MIL-C-17587. In fact, the Navy's own analysis conducted on surface combatants shows that electronic circuit breakers achieve a 70% increase in electrical coordination over older and competitive models.
Actron air circuit breakers are based on Groupe Schneider's Masterpact circuit breaker, the leading air circuit breaker in the world.
State Monitoring provides monitoring of the following features:
- Ground Fault
- Type & Phase of Last Trip
- Phase Current
- Current Data Logging
- Bidirectional Communication
- Remote Opening & Closing of Circuit Breaker
AC Single Phase Vacuum Power Circuit Breaker
- 11 - 24KV
- 25 - 50 - 60Hz
- 95 - 150 - 200 - 250KV
- Single Vacuum Bottle For All Ratings
Individualized Solutions
DC Circuit Breakers
- High Speed DC Circuit Breaker For On Board Applications
- 75 - 1500 - 3000VDC
- 1200 - 2400Amps
Individualized Solutions
|